Automatic Genset Control Modules
The automatic Genset control modules provide complete automatic control of
standby gas or diesel generator set engines. All fuel, ignition, and alarm relay
controls are via heavy-duty industrial type relay contacts eliminating the need
for external control power relays.
Many different models are available depending on your needs. Scroll down to
read a general description of each of our four different levels of automatic
control modules. More specific features are listed by model. Select any model heading below to view / download complete model specification data sheets, operating instructions, and typical wiring
diagrams.
For convenience, use our
Selection Guide to assist in choosing the
correct engine control for your application.
We offer many more special models (not listed here) which usually consist of
the following basic control modules with specialized software and/or hardware to meet your
specific needs. We welcome the opportunity to review and discuss your specific
requirements.
Note: The word "Level" used in classifying our controls (i.e. Level 2)
refers only to the relative level of complexity of each product family and does
not directly correspond to any other specifications.
Level 2 Controls
\ Level 1 Controls \
Level 0 Controls \
Remote Start/Stop

Level 2
Controls
A122E \
A122D \
A122A
The Level 2 Genset Control Modules are ideal for systems involving
NFPA-110 requirements, or any other application where pre-alarms or variable
start/stop time delays are desired.
The Level 2 controls can also be combined with an
Interface Adapter via a data-link cable to add many
other desirable functions including remote serial communications (RS232 &
RS485), additional I/O, battery voltage monitoring, remote annunciation, and
more. Go to the Interface Adapter section for more
information or contact us for your requirements.
Features
common on all Level 2 controls:
 |
Models for both 12VDC and 24VDC
systems.
|
 |
Local or Remote Control.
|
 |
Five (5) Shutdown Alarm Lights
with alarm relay control.
|
 |
Two (2) Pre-Alarm Alarm Lights.
|
 |
External Lamp-Test Provisions.
|
 |
Alarm Silence Provisions.
|
 |
10-amp Crank and Fuel Solenoid
Relays.
|
 |
2-amp Alarm Relay.
|
 |
Variable Time Delays
for engine start-up and shutdown.
|
 |
Selectable Cranking Modes.
|
 |
Provisions to test the overspeed
trip point at rated generator frequency for ease of generator set preparation.
|
 |
Pluggable terminal blocks for ease of installation
and service.
|
 |
Engine speed input signal may be
obtained from any source related to the engine speed.
|
 |
Loss of speed signal protection.
|
Additional features for Level 2 controls by model number:
-
-
 |
10-amp Main
Circuit Breaker Shunt Trip
alarm relay. |
 |
Emergency Stop and
flashing "Off-Auto" light outputs (with lamp-test) per NFPA-110. |
 |
System Normal light output
(with lamp-test). |
-
-
-
 |
Emergency Stop and
flashing "Off-Auto" light outputs (with lamp-test) per NFPA-110. |
 |
System Normal light output
(with lamp-test). |
-
-
-
 |
Emergency Stop light output. |

Level 1
Controls
A121CB \
A121C \
A121B \
A121A
The Level 1 Genset controls are ideal for systems, or any other application where
conventional 4 or 5-alarm shutdowns are desired.
Features
common on all Level 1 controls:
 |
Models for both 12VDC and
24VDC systems. |
 |
Local or Remote Control. |
 |
External Lamp-Test Provisions. |
 |
10-amp Crank and Fuel Solenoid
Relays. |
 |
Selectable Time Delays for
engine start-up and shutdown. |
 |
Selectable Cranking Modes. |
 |
Engine speed input signal may
be obtained from any source related to the engine speed. |
 |
Loss of speed signal
protection. |
Additional features for Level 1 controls by model number:
-
-
-
-
-
 |
Pluggable terminal blocks for ease of installation
and service. |
 |
Five (5) alarm light
outputs with alarm relay control. |
 |
2-amp Alarm Relay. |
-
-
-
 |
Four (4) alarm light
outputs with alarm relay control. |
 |
2-amp Alarm Relay. |
-
-
-
 |
Pluggable terminal blocks for ease of installation
and service. |
 |
Five (5) alarm light
outputs. |
 |
2-amp Glow Control Relay (for
engine pre-heat applications.) |
-
-
-
 |
Four (4) alarm light
outputs. |
 |
2-amp Glow Control Relay (for
engine pre-heat applications.) |

Level 0
Controls
A120C \
B120C \
A120A \
B120A
The Level 1 Genset controls are ideal for systems, or any other application where
conventional 4 or 5-alarm shutdowns are desired.
 |
Models for 12VDC systems only.
|
 |
Automatic Lamp Test (no
external button required.)
|
 |
Local or Remote Control.
|
 |
20-amp Crank and Fuel
Solenoid Relays.
|
 |
Selectable Cranking Modes.
|
 |
Engine speed input signal
obtained from 120VAC 60Hz Main Generator.
|
 |
Loss of speed signal protection.
|
 |
Optional pluggable terminal
blocks for ease of installation.
|
Additional features for Level 0
controls by model number:
-
-
 |
Five (5) alarm light
outputs. |
 |
Factory selectable Time Delays
for engine start-up and shutdown. |
-
-
-
 |
Packaged for direct mounting
to inside surface of customer control panel. |
 |
Five (5)
on-board alarm lights. |
 |
Factory selectable Time Delays
for engine start-up and shutdown. |
-
-
-
 |
Four (4) alarm light
outputs. |
 |
Selectable Time Delays
for engine start-up and shutdown. |
-
-
-
 |
Packaged for direct mounting
to inside surface of customer control panel. |
 |
Four (4)
on-board alarm lights. |
 |
Selectable Time Delays
for engine start-up and shutdown. |

Remote Start/Stop Controls
RSS3 \
RSS4
The Remote Start/Stop Genset Control Modules are ideal for
air or water-cooled systems with a single alarm requirement.
 |
Models for 12VDC systems only.
|
 |
Local or Remote Control.
|
 |
Selectable Cranking Modes.
|
 |
Selectable Time Delay for
engine start-up.
|
 |
Loss of speed signal protection.
|
Additional features for
Remote Start/Stop
controls by model number:
-
-
 |
For use with
Air-cooled or Water-cooled engines. |
 |
Shutdown
protection for: Overspeed, Overcrank, and Loss of Generator Frequency. |
 |
Additional
shutdown input for use with: High Water or High Head Temperature, Low
Oil Pressure, etc. |
 |
10-amp Crank
and Fuel Solenoid Relays. (20-amp relays available.) |
 |
Engine speed input signal
obtained from 120VAC 60Hz Main Generator frequency. |
-
-
-
 |
For use with
Air-cooled engines. |
 |
Shutdown
protection for: Overcrank and Loss of Generator frequency. |
 |
20-amp Crank
and Fuel Solenoid Relays. |
 |
Engine speed input signal
obtained from 120VAC 60Hz Main Generator voltage. |

|